17-10
Command Reference Guide
/ON Switch Plug(s) ON (RSM-8R8 Series Units Only)
Switches selected plugs(s) or Plug Group(s) On, as described in Section 9.3.2.
Notes:
• ThiscommandisnotavailableonstandardTSMSeriesandstandardRSM
Seriesunits.TheOncommandisonlyavailableonRSM-8R8Seriesunits.
• Whenthe/ONcommandisusedtoswitchmorethanoneplug,theBoot/
SequenceDelayPeriodswillbeappliedasdescribedinSection5.7.
• WhenthiscommandisinvokedinAdministratorModeorSuperUserMode,
itcanbeappliedtoallplugsandPlugGroupsontheRSM-8R8Seriesunit.
WhenthiscommandisinvokedinUserMode,itcanonlybeappliedtothe
plugsand/orPlugGroupsthathavebeenenabledforyouraccount.
Availability: Administrator, SuperUser, User
Format: /ON <n>[,Y] [Enter]
Where:
n The number or name of the plug(s) or Plug Group(s) that you intend to
Switch On. To apply the command to several plugs, enter a plus sign (+)
between each plug number. To apply the command to a range of plugs,
enter the numbers for the first and last plugs in the range, separated by a
colon character (:). To apply the command to all plugs allowed by your
account, enter an asterisk character (*).
,Y (Optional) Suppresses the command confirmation prompt.
Example:
Assume that your account allows access to Plug 2 and Plug 3. To switch Plugs 2 and
3 On, without displaying the optional command confirmation prompt, invoke following
command line:
/ON 2+3,Y [Enter]