5. Select in the Network view the IO device ‘VIPA MICRO PLC’ and switch to the
Device overview.
ð
In the Device overview of the PROFINET IO device ‘VIPA MICRO PLC’ the
CPU is already placed at slot 0.
1. As Ethernet PG/OP channel place at slot 4 the Siemens CP 343-1 (6GK7
343-1EX30 0XE0 V3.0).
2. Open the "Property" dialog by clicking on the CP 343-1EX30 and enter for the CP at
"Properties" at "Ethernet address" the IP address data, which you have assigned
before. You get valid IP address parameters from your system administrator.
1 Ethernet PG/OP channel
Device overview
Module ... Slot ... Type ...
PLC ... 2 CPU 314C-2PN/DP
Configuration of Ethernet
PG/OP channel
VIPA SPEED7
Motion control - Simple Motion Control Library
Usage Sigma-5/7 Pulse Train > Usage in Siemens TIA Portal