8. Navigate to your working directory and install the according GSDML file.
ð
After the installation the hardware catalog is refreshed and the Siemens TIA
Portal is closed.
After restarting the Siemens TIA Portal the according PROFINET IO device can
be found at Other field devices > PROFINET > IO > VIPA GmbH > ....
Thus, the VIPA components can be displayed, you have to deactivate the
"Filter" of the hardware catalog.
13.5.6.2 Hardware configuration
13.5.6.2.1 Hardware configuration System MICRO
To be compatible with the Siemens SIMATIC TIA Portal the following steps should be
executed:
1. Start the Siemens TIA Portal with a new project.
2. Switch to the Project view.
3. Click in the Project tree at ‘Add new device’ .
4. Select the following CPU in the input dialog:
SIMATIC S7-300 > CPU 314C-2 PN/DP (314-6EH04-0AB0 V3.3)
ð
The CPU is inserted with a profile rail.
Device overview:
Module ... Slot ... Type ...
PLC... 2 CPU 314C-2PN/DP
MPI interface... 2 X1 MPI/DP interface
PROFINET inter-
face...
2 X2 PROFINET interface
DI24/DO16... 2 5 DI24/DO16
AI5/AO2... 2 6 AI5/AO2
Add CPU in the project
VIPA SPEED7
Motion control - Simple Motion Control Library
Usage inverter drive via Modbus RTU > Usage in Siemens TIA Portal
HB00 | OPL_SP7 | Operation list | en | 18-30 487