A hardware configuration to enable the PtP functionality is not necessary.
1. Turn off the power supply.
2. Mount the extension module.
3. Establish a cable connection to the communication partner.
4. Switch on the power supply.
ð
After a short boot time the interface X1 PtP is ready for PtP communication.
1. As Ethernet PG/OP channel place at slot 4 the Siemens CP 343-1 (6GK7
343-1EX30 0XE0 V3.0).
2. Open the "Property" dialog by clicking on the CP 343-1EX30 and enter for the CP at
"Properties" at "Ethernet address" the IP address data, which you have assigned
before. You get valid IP address parameters from your system administrator.
1 Ethernet PG/OP channel
Device overview
Module ... Slot ... Type ...
PLC ... 2 CPU 314C-2PN/DP
MPI/DP interface 2 X1 MPI/DP interface
PROFINET inter-
face
2 X2 PROFINET interface
... ... ...
CP 343-1 4 CP 343-1
... ... ...
Enable PtP functionality
Configuration of Ethernet
PG/OP channel
VIPA SPEED7
Motion control - Simple Motion Control Library
Usage inverter drive via Modbus RTU > Usage in Siemens TIA Portal
HB00 | OPL_SP7 | Operation list | en | 18-30 489