13.7.3.30 FB 834 - VMC_WriteDriveParameter - write drive parameter
An overview of the drive systems, which can be controlled with this block
can be found here:
Ä
Chap. 13.7.1 ‘Overview’ page 542
With VMC_WriteDriveParameter the value of the parameter is written to the connected
drive.
Parameter
Parameter Declaration Data type Description
Axis IN_OUT MC_AXIS_REF Reference to the axis
Execute INPUT BOOL
n Write drive parameter data
Edge 0-1: The drive parameter data is written.
Index INPUT WORD Index of the drive parameter
Subindex INPUT BYTE Subindex of the drive parameter
Length INPUT BYTE Length of data
n 1: BYTE
n 2: WORD
n 4: DWORD
Value INPUT DWORD Value of the written parameter
Done OUTPUT BOOL
n Status
TRUE: Job successfully done. Parameter data was
read
Busy OUTPUT BOOL
n Status
TRUE: Job is running
Error OUTPUT BOOL
n Status
TRUE: An error has occurred. Additional error infor-
mation can be found in the parameter ErrorID.
ErrorID OUTPUT WORD Additional error information
Ä
Chap. 13.10 ‘ErrorID - Additional error information’
page 637
n Job start in each PLCopen-State possible.
The writing of the parameter data is started with an edge 0-1 at Execute. Busy is TRUE
as soon as writing of parameter data is running. After the parameter data was written,
Busy with FALSE and Done with TRUE is returned.
An active job continues to run even when Execute is set to FALSE.
Description
PLCopen-State
Write drive parameter data
VIPA SPEED7
Motion control - Simple Motion Control Library
Blocks for axis control > Complex motion tasks - PLCopen blocks
HB00 | OPL_SP7 | Operation list | en | 18-30 602