QTYP/ZTYP IND = 1 IND = 2
Data word Defi-
nition
DW-No., where the stored data starts DW-No., where the stored data starts
Valid range 0.0 ... 2047.0 0.0 ... 2047.0
Length Defini-
tion
Length of the DBs in byte Length of the DBs in byte
Valid range 8 fix 16 fix
Indirect addressing means that QANF / ZANF points to a memory area where the
addresses of the source res. destination areas and the indicator word are stored. In this
context you may either define one area for data source, destination and indicator word
(IND = 5) or each, data source, data destination and the indicator word, get an area of
their own (IND = 6). The following table shows the possible QANF / ZANF parameters for
indirect parameterization:
QTYP/ZTYP IND = 5 IND = 6
Definition Indirect addressing for source or destination param-
eters and indicator word (ANZW). The source or
destination parameters and ANZW are stored in a
DB in a sequential order.
QANF/ZANF
Indirect addressing for source and destination parameters and
indicator word (ANZW). The source and destination parame-
ters and ANZW are stored in a DB in a sequential order.
QANF/ZANF
DW +0 Data type source Description data
source/ destination
DW +0 Data type source Description data source
+2 DB-Nr. at type
"DB", otherwise
irrelevant
+2 DB-Nr. at type "DB",
otherwise irrelevant
+4 Start address +4 Start address
+6 Length in Byte +6 Length in Byte
+8 Data type destina-
tion
Description indi-
cator word
+8 Data type destination Description data destina-
tion
+10 DB-Nr. at type
"DB", otherwise
irrelevant
+10 DB-Nr. at type "DB",
otherwise irrelevant
+12 Start address +12 Start address
+14 Length in Byte
+16 Data type source Description indicator
word
+18 DB-Nr. at type "DB",
otherwise irrelevant
+20 Start address
valid DB-No. 0 ... 32767 0 ... 32767
Data word
Definition
DW-Nr., where the stored data starts DW-Nr., where the stored data starts
Valid range 0.0 ... 2047.0 0.0 ... 2047.0
Length Defini-
tion
Length of the DBs in byte Length of the DBs in byte
Valid range 14 fix 22 fix
Indirect parameterization
of source and destination
details and ANZW
(IND = 5 or IND = 6)
VIPA SPEED7
System Blocks
Fetch/Write Communication > SFC 230 ... 238 - Page frame communication
HB00 | OPL_SP7 | Operation list | en | 18-30 889