1-5
View
System view
Parameters
timer-value: Setting (in centiseconds) of the GARP LeaveAll timer. You need to set this argument with
the Leave timer settings of other Ethernet ports as references. That is, this argument needs to be larger
than the Leave timer settings of any Ethernet ports. Also note that this argument needs to be a multiple
of 5 and cannot be larger than 32,765.
Description
Use the garp timer leaveall command to set the GARP LeaveAll timer.
Use the undo garp timer leaveall command to restore the default setting of the GARP LeaveAll timer.
By default, the LeaveAll timer is set to 1,000 centiseconds, that is, 10 seconds.
In networking, you are recommended to set the GARP LeaveAll timer to 12000 centiseconds (2
minutes).
Related commands: display garp timer.
Examples
# Set the GARP LeaveAll timer to 100 centiseconds.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] garp timer leaveall 100
reset garp statistics
Syntax
reset garp statistics [ interface interface-list ]
View
User view
Parameters
interface-list: Specifies a list of Ethernet ports. In this list, you can specify individual ports and port
ranges. An individual port takes the form of interface-type interface-number and a port range takes the
form of interface-type interface-number1 to interface-type interface-number2, with interface-number2
taking a value greater than interface-number1. The total number of individual ports and port ranges
defined in the list must not exceed 10.