EasyManua.ls Logo

3Com 5500-EI PWR - Remote-Ping-Server Tcpconnect; Remote-Ping-Server Udpecho

3Com 5500-EI PWR
1314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-40
Related commands: remote-ping-agent enable, remote-ping-server tcpconnect,
remote-ping-server udpecho.
Examples
# Enable a remote-ping server.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] remote-ping-server enable
remote-ping-server tcpconnect
Syntax
remote-ping-server tcpconnect ip-address port-number
undo remote-ping-server tcpconnect ip-address port-number
View
System view
Parameters
ip-address: IP address specified for a TCP listening service on the remote-ping server.
port-number: Port number specified for a TCP listening service on the remote-ping server. The value
ranges from 1 to 50000. It is not recommended to use some special ports (that is, those used for fixed
functions, such as port 1701). Otherwise, the remote-ping test may fail.
Description
Use the remote-ping-server tcpconnect command to create a TCP listening service on the
remote-ping server.
Use the undo remote-ping-server tcpconnect command to remove the created TCP listening
service.
When performing a TCP connection test on a specified port of a remote-ping client, you must create a
TCP listening on the remote-ping server if the server is an switch; otherwise, the TCP test may fail.
Related commands: remote-ping-server enable.
Examples
# Enable TCP listening, using 169.254.10.2 as the IP address and 9000 as the port number.
<Sysname> system-view
System View: return to User View with Ctrl+Z
[Sysname] remote-ping-server tcpconnect 169.254.10.2 9000
remote-ping-server udpecho
Syntax
remote-ping-server udpecho ip-address port-number
undo remote-ping-server udpecho ip-address port-number

Table of Contents