Removing the mechanical stop axis 3
Use this procedure to remove the mechanical stop.
NoteAction
Run the robot to a position that enables ac-
cess to the mechanical stop.
1
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot work-
ing area.
2
Remove the mechanical stop.3
Refitting the mechanical stop axis 3
Use this procedure to refit the mechanical stop.
NoteAction
Refit the mechanical stop with its attachment
screws.
1
DANGER
Make sure all safety requirements are met
when performing the first test run. These are
further detailed in the section First test run
may cause injury or damage on page 28.
2