6240B DC Voltage Current Source/Monitor Operation Manual
9.2 Source and Measurement Function
9-9
9.2 Source and Measurement Function
DC source and measurement: Source and measurement of DC voltage and current
Pulse source and measurement: Source and measurement of pulse voltage and current
(However, measurement auto range in pulse source is impossible)
DC sweep source and measurement: Source and measurement by linear, 2- slope linear, random and fixed
levels
Pulse sweep source and measurement:
Source and measurement by linear, 2- slope linear, random and fixed
levels
(However, measurement auto range in pulse source is impossible)
Low-resistance measurement: Measurement by pulse current source voltage measurement
Integration time: 9 types: 100 s, 500 s, 1 ms, 5 ms, 10 ms, 1 PLC, 100 ms, 200 ms and
S/H
S/H: Sample hold (integration time: 100 s) measurement
(Enabled only in the pulse source or pulse sweep source modes)
(PLC: Power Line Cycle 50 Hz: 20 ms, 60 Hz: 16.66 ms)
Sweep mode: Reverse ON (round) / OFF (one way)
Sweep repeat count: 1 to 1000 times or infinite
Maximum number of sweep steps: 8000 steps
Maximum random sweep memory: 8000 data
Measurement data memory: 8000 data
Measurement auto range: Available only in VSIM or ISVM
Measurement function link mode: Links the source function to the measurement function.
(VSIM or ISVM)
ON/OFF available
Limiter: The HI and LO limit values can be set individually.
(However, setting the current limit values with the same polarity is not
allowed.)
Calculation function: NULL calculation
Comparator calculation (HI, GO, or LO)
Scaling calculation
MAX, MIN, AVE and TOTAL calculations
Trigger style: Auto trigger, External trigger
Output terminal: Front; Safety socket
HI OUTPUT, HI SENSE, LO OUTPUT, and LO SENSE
Maximum input: 15 V peak (between HI-LO)
2 V peak (between OUTPUT and SENSE)
250 V maximum (between LO and chassis)
Maximum remote sensing voltage: 1 V Max; HI OUTPUT - HI SENSE, LO OUTPUT - LO SENSE
(The voltage between HI SENSE and LO SENSE must be within the
maximum output voltage range.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADCMT 6240B and is the answer not in the manual?

ADCMT 6240B Specifications

General IconGeneral
BrandADCMT
Model6240B
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals