EasyManuals Logo

Agilent Technologies E4406A VSA Series User Manual

Agilent Technologies E4406A VSA Series
420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #238 background imageLoading...
Page #238 background image
238 Chapter5
Language Reference
MEASure Group of Commands
Power spectral
density
reference
not
specified
or n=1
Basic,
cdmaOne,
cdma2000,
W-CDMA
(3GPP), or
W-CDMA
(Trial &
Arib) mode
Returns 24 comma-separated scalar results, in the following
order:
1. Upper adjacent chan center frequency - relative power (dB)
2. Upper adjacent chan center frequency - absolute power
(dBm/Hz)
3. Lower adjacent chan center frequency - relative power (dB)
(same as upper)
4. Lower adjacent chan center frequency - absolute power
(dBm/Hz) (same as upper)
5. Negative offset frequency (1) - relative power (dB)
6. Negative offset frequency (1) - absolute power (dBm/Hz)
7. Positive offset frequency (1) - relative power (dB)
8. Positive offset frequency (1) - absolute power (dBm/Hz)
...
23.Positive offset frequency (5) - relative power (dB)
24.Positive offset frequency (5) - absolute power (dBm/Hz)
2
NADCand
PDC mode
Returns 10 comma-separated scalar values of the pass/fail
(0=passed, or 1=failed) results determined by testing the
absolute power of the offset frequencies:
1. Negative offset frequency (1) absolute power
2. Positive offset frequency (1) absolute power
...
9. Negative offset frequency (5) absolute power
10.Positive offset frequency (5) absolute power
2
iDEN
mode
Returns 3 comma-separated scalar values of the histogram
absolute power trace:
1. Lower offset frequency absolute power
2. Reference frequency absolute power
3. Upper offset frequency absolute power
Total power
reference
2
Basic,
cdmaOne,
cdma2000,
W-CDMA
(3GPP), or
W-CDMA
(Trial &
Arib) mode
Returns 11 comma-separated scalar values (in dBm)
corresponding to the total power histogram display. The values
are returned in ascending frequency order:
1. Negative offset frequency (5)
2. Negative offset frequency (4)
...
6. Center frequency
7. Positive offset frequency (1)
...
11.Positive offset frequency (5)
Measurement
Type
n Results Returned

Table of Contents

Other manuals for Agilent Technologies E4406A VSA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E4406A VSA Series and is the answer not in the manual?

Agilent Technologies E4406A VSA Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelE4406A VSA Series
CategoryTest Equipment
LanguageEnglish

Related product manuals