Error Messages
Error Message Descriptions
GSM - Specific Error Messages
[100 to 199]
An error number in the range [100 to 199] indicates the instrument has
detected an error relating to the GSM personality.
GSM - Specific Error Message Descriptions
(Number) Description
(100) Not enough data to fit into GSM mask
An attempt to position a GSM trace into the mask,
when not enough data was present. Try using the
Restart key to clear the problem. This can be caused by
a bad GSM burst, or the RF Sync Delay set too far.
(101) GSM burst out of limits
The GSM signal did not fit into the mask in the Power
vs. Time measurement.
(102) Insufficient pre-Trig for demod - decrease
Trig Delay
(103) Incorrect RBW for demod - change RBW
(104) Invalid GSM burst timing
A GSM-like burst was acquired, but it’s timing is not
valid. Ensure the correct
Burst Type has been selected.
(105) Valid GSM burst not found
In a GSM measurement, data was acquired but a GSM
burst was not found.
(106) Cannot synchronize frame trigger
Cannot synchronize the frame trigger to the even
second clock.
(107) Dynamic range not optimum - set AUTO RF input
(108) Cannot synchronize to RF amplitude (burst
error)
(109) GSM RF sync delay is out of range
Change RF Sync Delay.

Table of Contents

Other manuals for Agilent Technologies E4406A VSA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E4406A VSA Series and is the answer not in the manual?

Agilent Technologies E4406A VSA Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelE4406A VSA Series
CategoryTest Equipment
LanguageEnglish

Related product manuals