2-51
Confidential
Error code 5001
Printable pages set for PF kit MP have reached the upper limit.
Error code 5002
Printable pages set for PF kit 1 have reached the upper limit.
Error code 5003
Printable pages set for PF kit 2 have reached the upper limit.
Error code 5004
Printable pages set for PF kit 3 have reached the upper limit.
Error code 5005
Printable pages set for PF kit 4 have reached the upper limit.
Error code 5006
Printable pages set for PF kit 5 have reached the upper limit.
Error code 6001
The front cover sensor detected that the front cover was open.
Step Cause Remedy
1
End of life of the applicable PF
kit
Replace the applicable PF kit. Refer to “1.3.22
Reset counters for consumable parts (function
code: 88)” in Chapter 5 to reset the applicable
PF kit counter after the replacement.
2
If the error display is not cleared
after the applicable PF kit
counter has been reset, the
main PCB is faulty.
Replace the main PCB ASSY.
<User Check>
Close the front cover.
Step Cause Remedy
1
Connection failure of the front
cover sensor harness
Reconnect the front cover sensor harness.
2
Connection failure of the relay
front harness
Reconnect the relay front harness.
3
Front cover sensor attachment
failure
Reattach the front cover sensor.
4 Front cover failure Replace the front cover.
5 Front cover sensor failure Replace the relay front PCB ASSY.
6 Relay front PCB failure Replace the relay front PCB ASSY.
7 Main PCB failure Replace the main PCB ASSY.