EasyManua.ls Logo

Dasan V8102 - System Temperature

Dasan V8102
910 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UMN:CLI User Manual
V8102
124
To display the configured threshold of fan operation, use the following command.
Command
Mode
Description
show status fan
Enable/Global
Shows the status and configured threshold of
fan operation.
6.1.6.4 System Temperature
To set the threshold of system temperature, use the following command.
Command
Mode
Description
threshold temp HIGH_VALUE
LOW_VALUE
Global
Sets the threshold of system temperature(°C).
HIGH_VALUE: overload system temperature (-40 to
100°C)
LOW_VALUE: underload system temperature (-40 to
100°C)
threshold temp iu NUMBER
HIGH_VALUE LOW_VALUE
Sets the threshold of IU temperature(°C).
NUMBER : a slot number of IU
HIGH_VALUE: overload system temperature (-40 to
100°C)
LOW_VALUE: underload system temperature (-40 to
100°C)
no threshold temp
Deletes the configured threshold of system/IU tempera-
ture.
no threshold temp iu NUMBER
To enable/disable the system/IU shut down due to over-temperature event that can lead
to serious system problems, use the following command.
Command
Mode
Description
threshold power iu
SLOT_NUMBER VALUE
Global
Sets the over-temperature threshold value of interface
unit.
VALUE: temperature threshold for IU power-off (60 to
90°C, default: 80°C)
threshold power system VALUE
Sets the over-temperature threshold value of chassis
system.
VALUE: temperature threshold for system shut-down
(80 to 120°C, default: 110°C)
threshold power system { ena-
ble | disable }
Enables/disables the system shut down in the over-
temperature event.
no threshold power iu
SLOT_NUMBER
Deletes the configured over-temperature threshold
value of IU/system.
no threshold power system
To display the configured threshold of system temperature, use the following command.