6-20 Removal and Replacement
Ribbon Index Sensor
Removal Procedure
1. Unplug the printer.
2. Remove the ribbon cartridge and cleaning roller.
3. Remove the
Main Enclosure (p. 6-8).
4. Optional: For easier access, you may choose to remove the
Ribbon Guide
(p.
6-42).
5. Unplug the sensor from the main control board.
6. Pull the sensor off the mounting post on the ribbon guide. Pry underneath
with a screwdriver if necessary.
Replacement Notes
Route the cable through the ribbon guide as shown below.
Refer to the Front Wire Routing and Functional Block Diagram for
replacement details.
Use the sensor display in Diagnostics to verify the sensor changes state as the
ribbon is advanced.