6-84 Removal and Replacement
Smart Card Contact
Removal Procedure
1. Unplug the printer.
2. Remove the ribbon cartridge and cleaning roller.
3. Remove the
Main Enclosure (p. 6-8).
4. Remove the
Transport Assembly from the base (p. 6-29).
5. Disconnect the interface cable from the smart card interface board. Refer to
the
Functional Block Diagram (p. 6-6) for location and details.
6. Remove the
Ribbon Motor (p. 6-27).
7. Remove the
Solenoid Link from the rocker (p. 6-82).
8. Remove the smart card contact carrier:
A. Insert a screwdriver between the carrier and the left mounting tab.
B. Twist the blade to pry the carrier out of the mounting tab.