EasyManua.ls Logo

Dell PowerConnect B-RX - Page 1379

Dell PowerConnect B-RX
1458 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BigIron RX Series Configuration Guide 1303
53-1002253-01
Syslog messages
A
Notification Module was inserted to slot <slot-num> Indicates that a module was inserted into a
device slot.
The <slot-num> is the number of the device
slot into which the module was inserted.
Notification Module was removed from slot <slot-num> Indicates that a module was removed from a
device slot.
The <slot-num> is the number of the device
slot from which the module was removed.
Notification ACL insufficient L4 session resource, using
flow based ACL instead
The device does not have enough Layer 4
session entries.
To correct this condition, allocate more
memory for sessions. To allocate more
memory, enter the following command at the
global CONFIG level of the CLI interface.
system-max session-limit <num>
Notification ACL exceed max DMA L4 cam resource, using
flow based ACL instead
The port does not have enough Layer 4 CAM
entries for the ACL.
To correct this condition, allocate more Layer
4 CAM entries. To allocate more Layer 4 CAM
entries, enter the following command at the
CLI configuration level for the interface.
ip access-group max-l4-cam <num>
Notification ACL insufficient L4 cam resource, using flow
based ACL instead
The port does not have a large enough CAM
partition for the ACLs.
Notification ACL system fragment packet inspect rate
<rate> exceeded
The fragment rate allowed on the device has
been exceeded.
The <rate> indicates the maximum rate
allowed.
This message can occur if fragment thottling
is enabled.
Notification ACL port fragment packet inspect rate <rate>
exceeded on port <portnum>
The fragment rate allowed on an individual
interface has been exceeded.
The <rate> indicates the maximum rate
allowed.
The <portnum> indicates the port.
This message can occur if fragment thottling
is enabled.
TABLE 228 Brocade Syslog messages (Continued)
Message level Message Explanation

Table of Contents