Diagnostics and troubleshooting Troubleshooting
Digi TransPort WR Routers User Guide
286
10. Verify that the serial port is configured for 115200 baud, 8 databits, 1 stopbit, no flow control,
and no parity. Verify that the state setting of the serial interface is on. For example:
digi router > serial 1
baud 115200
databits 8
description
flowcontrol none
parity none
state cli
stopbits 1
11. If the serial configuration is incorrect, follow the instructions in Configure the serial interface to
set the correct configuration.
12. If you have verified that the serial ports on both the PCand the TransPort device are correctly
configured, and you still cannot access the command-line interface over the console, try
replacing the serial cable.
13. If serial issues persist after following these steps, contact Digi Technical Support, with the
subject lineSerial connectivity issues.