SNMP Commands
4-69
4
snmp-server view
This command adds an SNMP view which controls user access to the MIB. Use the
no form to remove an SNMP view.
Syntax
snmp-server view view-name oid-tree {included | excluded}
no snmp-server view view-name
view-name - Name of an SNMP view. (Range: 1-64 characters)
oid-tree - Object identifier of a branch within the MIB tree. Wild cards can
be used to mask a specific portion of the OID string. (Refer to the
examples.)
included - Defines an included view.
excluded - Defines an excluded view.
Default Setting
defaultview (includes access to the entire MIB tree)
Command Mode
Global Configuration
Command Usage
Views are used in the snmp-server group command to restrict user access
to specified portions of the MIB tree.
The predefined view “defaultview” includes access to the entire MIB tree.
Examples
This view includes MIB-2.
This view includes the MIB-2 interfaces table, ifDescr. The wild card is used to select
all the index values in this table.
Table 4-22 show snmp engine-id - display description
Field Description
Local SNMP engineID String identifying the local engine ID.
Local SNMP
engineBoots
The number of times that the engine has (re-)initialized since the snmp
EngineID was last configured.
Remote SNMP
engineID
String identifying an engine ID on a remote device.
IP address IP address of the device containing the corresponding remote SNMP
engine.
Console(config)#snmp-server view mib-2 1.3.6.1.2.1 included
Console(config)#
Console(config)#snmp-server view ifEntry.2 1.3.6.1.2.1.2.2.1.*.2 included
Console(config)#