b. Press F2 View Data to review the alignment data in the traditional cardinal
positions (0°, 90°, 180°, 270°). See Section 7.5.7 for more information on the View
Data screen.
c.
Press F4 Full Screen to display the plot in full screen.
d. Press F6 Switch Plot Type to switch the plot type to a four-quadrant tolerance plot,
a dual tolerance plot, a single vertical tolerance plot, or a single horizontal
tolerance plot.
On a four-quadrant tolerance plot, if the tolerance type is Standard, angular
misalignment data versus offset misalignment data is plotted for both the
vertical and horizontal directions. If the tolerance type is Jackshaft, left machine
angular misalignment versus right machine angular misalignment data is
plotted. In this plot, the positive and negative values for the reading sets are
plotted.
On a dual tolerance plot, the alignment data is plotted similar to a four-quadrant
tolerance plot, except the absolute value of each reading is plotted.
On a single tolerance plot, alignment data is plotted similar to a dual tolerance
plot, except the data plotted either for the vertical or horizontal direction only.
e. Press F7 Show All to display all acquired readings for the job.
By default, the tolerance plot shows only the last three acquired readings for the
job.
f. Press F8 Review Meas Data to review the alignment measurement results.
This is only available when reviewing of measurements results is enabled.
g. Press F11 Expand X Axis to expand the X axis by a factor of two.
h. Press F12 Compress X Axis to compress the X axis by a factor of two.
i. Press ALT > F3 Cursor Home to place the cursor to the most recent acquired
reading.
j. Press ALT > F4 Clear Cursor to remove the cursor from the plot.
k. Press ALT > F9 Cursor End to place the cursor to the oldest acquired reading.
7.8.2 Display sine fit data plot
You can review and manually condition or edit the sine curve data from the sine fit data
plot.
This option is available only if the alignment method is Auto Sweep, Manual Sweep, or Pass
Mode.
Prerequisites
The following steps let you view the sine fit data plot from the Review Measurements
screen. Make sure you have enabled reviewing of results. See Section 7.4.6.
Procedure
1. After acquiring alignment data, press Enter.
Advanced Laser Alignment
248 MHM-97432 Rev 7