c. Press F6 Switch Move Type to select a move type. You can choose vertical,
horizontal, or vertical and horizontal.
d.
Press F8 Data Detail to view the tolerance plots.
The tolerance plots are a graphical representation of the alignment condition of
the machine. See Section 7.8.1 for more information on the tolerance plots.
e. Press F10 Predict to estimate the resulting alignment condition based on a
theoretical adjustment prior to actually moving the machine.
This is useful in determining whether appropriate shims are available to correct
the misalignment.
See Section 7.5.9 for more information on using the predict mode.
f. Press F12 Live Move to observe the machine movement in real time from the
analyzer while making machine moves.
This option is present depending on the live move orientation you have
previously chosen. See Section 7.4.4.
3. If necessary, acquire alignment data again. See Section 7.5.3.
7.5.7 Review data in traditional cardinal positions
This option is available only for Advanced horizontal and vertical alignment jobs.
Use this option if you prefer to record data in the traditional cardinal positions (0°, 90°,
180°, and 270°) and if you want to perform a graphical solution using the data.
Procedure
From the tolerance plot, press F2 View Data.
You can view the tolerance plots from the Review Measurements screen or from the
Horizontal Move, Vertical Move, Dual Move, Angular Move, and Offset Move screens. See
Section 7.8.1 for more information on how to view the tolerance plots.
Advanced Laser Alignment
MHM-97432 Rev 7 221