031914 M3-17
Network Communication Ports: The
U1 Motion Control Module has
Network Ports located on top of the
module that are used for
communication with the Servo Drives
and Servo Motors under its control.
(Illustration 28) Only the X100 Port
and the X101 Port are currently used.
X100 Port: Communicates directly
with the U7 Servo Drive that
controls the Infeed Structure Lift.
X101 Port: Communicates with
the U3 Active Line Module, the
U4, U5, U6 and U7 Servo Drives.
The cable connects to the X200
Port on the U3 Active Line Module
and is sent in series from the
X201 Port to the U4, U5, U6 and
U7 Servo Drives.
ILLUSTRATION 28
U1 ETHERNET NETWORK