EasyManua.ls Logo

Fujitsu ETERNUS CS800 S5 - Page 78

Fujitsu ETERNUS CS800 S5
634 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Turning On and Shutting Down the System Hardware Description and Basic Operations
76 U41840-J-Z125-7-76
1. Scale variant only:
a) Switch on both PSU switches on the rear side of each storage base and expansion
module.
b) Check that the LINE LEDs of all storage expansion modules are green.
c) At the storage base module, press the power ON/OFF button which is located at the
front panel on the left side.
d) Wait until the READY LED of the storage base module glows green.
2. At the server module, press the power ON/OFF button which is located at the front
panel on the right side.
The server is switched on, performs a system test and boots the operating system.
3. Wait about 15 minutes before starting any further actions (such as configurations via
software).
Shutting Down the System
To shut down the ETERNUS CS800 S5, use the remote management pages (see "Reboot
& Shutdown" on page 447). Shutting down the system can take up to 15 minutes. The
server is switched off and goes into standby mode. The power-on indicator lights up orange.
I
If the operating system does not switch the server off automatically, press the
ON/OFF button for at least 10 seconds and/or send a corresponding control signal.
The storage modules are not switched off by shutting down the ETERNUS CS800 S5 via
the remote management pages. If you want to switch off the storage modules completely,
wait until the server has shut down, then press the Power ON/OFF button of the storage
base module(s) for several seconds until the READY LED does not glow any more. This
can take about 10 seconds.

Table of Contents