EasyManua.ls Logo

Fujitsu ETERNUS CS800 S5 - Turning on and Shutting down the System

Fujitsu ETERNUS CS800 S5
634 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Description and Basic Operations Turning On and Shutting Down the System
U41840-J-Z125-7-76 75
Table 17: 2.5’’ Hard Drive Disk Indicators
I
If a drive fails, you will be notified by an admin alert in the remote management
pages (see "Admin Alerts" on page 419).
Turning On and Shutting Down the System
Turning on the System
To turn on the ETERNUS CS800 S5, proceed as follows:
Entry model only:
1. Switch on the ETERNUS CS800 system by pressing the power buttons located on the
front of the system.
2. If storage module is installed, it is switched on automatically.
3. Wait 15 minutes for the system to boot before continuing with the procedure.
Item Indicator Description
1 LED 1
(green)
HDD BUSY
Lights up: HDD in active phase
Does not light: HDD inactive (drive inactive)
2 LED 2
(orange)
HDD FAULT
Does not light: no HDD error
Lights up: HDD Faulty or Rebuild Stopped (drive defective/needs
replacing, a rebuild process was stopped or the HDD module is not
correctly inserted)
Slow flashing: HDD Rebuild (the data is being restored after
changing a drive)
Fast flashing: HDD Identify
Four fast blinks/pause: HDD Predicted Fault
Two fast flashes/pause: HDD Hot Spare (Hot spare drive active.
The corresponding drive has failed).

Table of Contents