U41840-J-Z125-7-76 79
Installing the ETERNUS CS800 S5 Modules
I
It is recommended to install the ETERNUS CS800 S5 system in a controlled or
restricted area to prevent access by untrained personnel. In addition, it is
recommended that system installation is performed only by qualified IT personnel.
Installing the ETERNUS CS800 S5 modules in a rack consists of the following steps:
1. "Unpacking the Modules"
2. "Locating the Mounting Position" on page 81
3. "Installing the Components in the Rack" on page 84
4. "Cabling within the ETERNUS CS800 S5 System" on page 92
I
See "LAN Cabling" on page 98 and "VTL and PTT Cabling" on page 100 for
connecting the system to the network.
Necessary Tools
Provide the following tools for unpacking and installing the ETERNUS CS800 S5 system:
● #2 Phillips and Torx 20 screwdriver
Taking ESD Precautions
Some components within the ETERNUS CS800 S5 system contain static-sensitive parts.
To avoid damaging these parts while performing installation procedures, always observe
the following precautions:
● Keep the system turned off during all installation procedures.
● Keep static-sensitive parts in their original shipping containers until ready for instal-
lation.
● Do not place static-sensitive parts on a metal surface. Place them inside their protective
shipping bag or on an antistatic mat.
● Avoid touching connectors and other components.
I
Dry climates and cold-weather heating environments have lower relative
humidity and are more likely to produce static electricity.