Operation - Calibration
Part No.: 4418309_Rev09 Fusion4 MSC-L
Honeywell Installation & Operation Manual 5 - 273
The Calibration . Arm n . Additive Streams screen appears.
2. Select any one of the streams. For example, Stream 1.
The Calibration . Stream n . Wizard 1/6 screen appears, on which
the preset volume must be entered.
3. On the Calibration . Stream n . Wizard 1/6 screen, enter the preset
volume that the MSC-L must inject for the calibration process and
then select <Confirm>.
The Calibration . Stream n . Wizard 2/6 screen appears, on which
the delay time must be entered.