EasyManua.ls Logo

Hypertherm XPR460 - Page 142

Hypertherm XPR460
532 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 37 - Torch-lead assembly (continued)
4 Pilot arc lead
5 Coolant return hose (red)
6 Coolant supply hose (green)
7 Shield gas hose
8 Plasma gas hose A
9 Plasma gas hose B
10 To the torch
11 To the TorchConnect console
The 6 meter (20 feet) lead is compatible only with gas assemblies that
are 7.5 meters (24.6 feet) or less. For lengths, refer to Torch leads on
page 431.
1. Adjust the EasyConnect
torch-lead assembly so that the connectors in the torch-lead assembly align
with the related receptacles in the TorchConnect console.
2. Optional: If you use a third-party ohmic circuit, remove the plug (*) to get access to the ohmic wire.
3. Connect the torch-lead assembly to the TorchConnect console:
Use your hands to tighten the coupler on the torch-lead assembly. Do not use tools.
4. Connect the plasma valve cable to its connector.
Installation
3
142
811530 Instruction Manual XPR460

Table of Contents

Related product manuals