LED Signal LED Signal
D84 WiFi LED 1 D50 PLASMA START
D85 WiFi LED 2 D56 MOTION
D82 WiFi RX D64 COMMAND HOLD
D81 WiFi TX D53 HOLD IN
D80 REDUNDANT REMOTE ON/OFF D54 SHIELD PIERCE GAS
D52 RS-422 RX D61 CNC ERROR
D51 RS-422 TX D66 NOT READY FOR START
D4 A3.3 V D68 AUTO PIERCE DETECT
D49 USB FLAG D69 OHMIC CONTACT OUTPUT
D104 STATUS D15 SURGE INJ EN (UNUSED IN THIS SYSTEM)
D105 ACTIVITY D108 PILOT ARC ENABLE
D78 CAN RX D89 REMOTE ON-OFF RELAY ENABLE
D79 CAN TX D6 PILOT ARC RELAY
D33 MAGFAN 3 FEEDBACK D10 48 V POWER ENABLE
D31 MAGFAN 2 FEEDBACK D19 MAIN CONTACTOR
D28 MAGFAN 1 FEEDBACK D25 INRUSH CONTACTOR
D5 +3.3 V D100 COOLER ENABLE
D20 MAGNETICS FANS ENABLE D94 +15 V
D86 REMOTE ON-OFF D95 -15 V
D2 +24 V D3 +5 V
DIP switch positions
These DIP switch position details are for the control PCB in the plasma power supply.
DIP switch 1 positions
1 RS-422 RX termination Default is ON
2 RS-422 TX termination Default is OFF
3 Not used Default is OFF
4 CAN termination resistor ON = 121 ohms (Ω)
OFF = Open
Default is OFF