5. Supply power to the cutting system.
The change goes into effect after you remove and then supply power to the cutting system.
Reset the wireless module
It is possible to make mistakes when you set up the wireless module. Use this procedure to set your
wireless module to its default settings.
WARNING
ELECTRIC SHOCK CAN KILL
The plasma power supply contains dangerous electric voltages that
can seriously injure or kill you. Even if the plasma power supply is
turned OFF, you can still get a serious electric shock if the plasma
power supply remains connected to an electric power source.
Use extreme caution if you do diagnosis or maintenance tasks when
the plasma power supply remains connected to an electric power
source and the outer cover or panels are removed. All work that
requires removal of the plasma power supply outer cover or panels
must be done by a qualified technician. Refer to the Safety and
Compliance Manual (80669C) for more safety information.
WARNING
ELECTRIC SHOCK CAN KILL
The plasma power supply contains dangerous electric voltages that can seriously
injure or kill you. Even if the plasma power supply is turned OFF, you can still get
a serious electric shock if the plasma power supply remains connected to an
electric power source.
Use extreme caution if you do diagnosis or maintenance tasks when the plasma
power supply remains connected to an electric power source and the outer cover
or panels are removed.
1. Remove the power from the cutting system:
a. Set the line-disconnect switch to the OFF position.