Table 30 - Inspection, preventive maintenance, and cleaning tasks
Maintenance task or activity Daily Weekly Monthly Every 6
months
Do a test of the inlet pressures X
Examine all of the air filters X
Do a check of the coolant level and condition X
Examine and lubricate O-rings X
Examine the water tube and torch X
Examine hoses, cables, and leads X
Do tests for gas leaks X
Do a check of the coolant flow X
Clean inside the plasma power supply X
Examine the contactors X
Examine the pilot-arc relay X
Examine the coolant system X
Do the coolant flow test X
Examine the gas line connections X
Examine the hoses X
Examine the cables X
Examine the ground connections X
Examine the table-to-workpiece connection X
Replace the coolant and coolant filter, and clean and examine
the pump screen and coolant check valve
X
Daily inspections
Always do these tasks at least once daily, before system operation.
Examine the gas regulators on page 250
Examine the shield water regulator (if applicable) on page 250
Examine the connections and fittings on page 251
Remove the torch and consumable parts on page 143
Examine the torch lead on page 259