Adjustable settings
The CNC must allow the adjustment of the following settings:
■
Current setpoint
■
Plasma cutflow
■
Shield cutflow
■
Gas mixing setpoints
Display settings
The CNC must show the following data:
■
Plasma-gas type
■
Shield-gas type
■
Process-ID selection
■
System-diagnostic codes
■
Firmware version based on console type
The CNC must show the following data in real time to troubleshoot and diagnose system operation:
■
Chopper current
■
Work-cable current
■
System-status codes
■
Chopper temperature
■
Transformer temperature
■
Coolant temperature
■
Coolant flow
■
Process-gas pressures
■
Fan speeds
Diagnostics and troubleshooting
The CNC must be able to run the following commands to diagnose and troubleshoot system operation:
■
Test preflow gases
■
Test pierceflow gases
■
Test cutflow gases
■
Test for gas system leaks