f. Remove the hose clamp from the pilot-arc, coolant, and shield-water assembly, put it in the
groove on the console collar.
g. Put the assembly coupler on the console collar and tighten the hose clamp.
Connect the power, CAN, and 5-gas assembly for VWI or OptiMix
Use this information to connect the power cable, CAN cable, oxygen hose, air hose, argon hose, nitrogen
hose, and H
2
-mix or F5 hose to the VWI or OptiMix gas connect console and TorchConnect console.
Figure 35 - Power, CAN, and 5-gas hose assembly
1 Power cable
2 CAN cable
3 Oxygen hose, blue
4 Air hose, black
5 Argon hose, black
6 Nitrogen hose, black
7 H
2
-mix or F5 hose, red
8 To the gas connect console
9 To the TorchConnect console
For lengths, refer to Power, CAN, and 5-gas assemblies (VWI, OptiMix)
on page 427.
Installation
3
126
811530 Instruction Manual XPR460