Install the torch in the torch mounting bracket
Install the torch in the torch mounting bracket. Make sure it is level in all directions, then tighten the screws
on the bracket.
Before you begin:
■
You must connect the torch-lead assembly to the torch receptacle. Refer to Install the torch-lead
assembly to the torch receptacle on page 136.
■
You must remove the consumables from the torch. Refer to Remove the torch and consumable parts
on page 143.
■
You must install the torch into the torch receptacle. Refer to Install the torch into the torch receptacle
on page 145.
■
As the installer or user, you must supply the torch mounting bracket for your cutting system.
□
Select one that complies with the requirements in Torch mounting bracket requirements on
page 70.
□
Mounting brackets are available from Hypertherm. Refer to Torch bracket on page 419.
■
The XPR torch mounting sleeve is larger than the HPR torch mounting sleeve. Modification or
replacement of an HPR mounting sleeve is necessary before you install an XPR torch.
1. Remove the power from the cutting system:
a. Set the line-disconnect switch to the OFF position.
b. Make sure that the power-indicator LED is not illuminated on the plasma power supply or
other system components.
2. Install the torch mounting bracket onto the torch lifter.
Refer to the instruction manual for the torch lifter for information about how to install the torch
mounting bracket in the torch lifter.
3. Insert the torch, with the attached torch-lead assembly, into the torch mounting bracket, as shown.
Installation
3
147811530Instruction ManualXPR460