DC: Direct current, current
■
Ind: Inductor
■
MAGFAN: Magnetics fan
■
Cooler Fan Tach: Cooler fan tachometer
Table 33 - Diagnostic codes in the web interface
Type Description
Information These codes contain information about the current conditions. In many cases, operator action is not
necessary for Information codes. If action is necessary, the steps are usually simple.
Alert These codes are for conditions that can decrease productivity or quality. Find a solution to an
Alert code as soon as possible.
Error These codes are for conditions that usually decrease productivity or quality, or cause damage to cut-
ting system components. Find a solution to an Error code as soon as possible.
Failure These codes are for conditions where you cannot start the arc until the condition is resolved. Failure
mode protects the cutting system and system components from permanent damage.
Certain codes can occur if the cutting system has old firmware. Make
sure that you have the most recent XPR firmware. Log into the Xnet at
www.hypertherm.com to download it.
If you cannot find or resolve the problem with the corrective actions in
Diagnostic codes on page 278, speak to your cutting machine supplier
or regional Hypertherm Technical Service team.
Diagnostic codes
Use this table to identify a diagnostic code and where to find more troubleshooting information about it.
Table 34 - Diagnostic code descriptions
Code Priority Description
XPR
models
Corrective action
500 Failure GCC->Main CAN t/o All models CAN communication troubleshooting for gas connect
consoles on page 311
501 Failure Mix->Main CAN t/o All models CAN communication troubleshooting for mixing mod-
ules in OptiMix consoles on page 313
503 Failure TCC->Main CAN t/o All models CAN communication troubleshooting for TorchCon-
nect consoles on page 316
Diagnostics and Troubleshooting
8
278
811530 Instruction Manual XPR460