EasyManua.ls Logo

Hypertherm XPR460 - Troubleshooting for Start Switch Faults; Diagnostic Codes 570, 571, 574 - 577

Hypertherm XPR460
532 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 35 - Minimum and maximum ohmic resistance values for thermistors
Thermistor temperature Minimum resistance (Ohms) Maximum resistance (Ohms)
25°C (77°F) 9,000 11,000
35°C (95°F) 5,000 7,000
45°C (113°F) 3,900 4,900
55°C (131°F) 2,500 3,500
65°C (149°F) 1,500 2,500
75°C (167°F) 1,000 2,000
85°C (185°F) 750 1,250
95°C (203°F) 600 1,000
105°C (221°F) 400 800
115°C (239°F) 300 600
125°C (257°F) 200 500
135°C (275°F) 150 400
145°C (293°F) 150 250
155°C (311°F) 125 225
165°C (329°F) 100 175
Troubleshooting for start switch faults
Diagnostic codes 570, 571, 574 – 577
Diagnostic codes 570 – 577 can identify problems with the CNC, PCB, discrete cable, or the D50 LED
on the control PCB (PCB 1) in the plasma power supply.
Diagnostics and Troubleshooting
8
335811530Instruction ManualXPR460

Table of Contents

Related product manuals