Chopper current
If the Ignite state (8) does not complete in 500 milliseconds, continue troubleshooting steps to identify
the problem.
Refer to Initial inspection steps on page 273 for troubleshooting procedures.
Pilot Arc state (9)
During the Pilot Arc state (9), the system does a check for correct coolant flow, gas pressures,
temperatures, DC bus voltage, chopper current, and work cable current. The Pilot Arc state (9) must be
completed in 500 milliseconds or less.