Table 3 - Ecodesign requirements and data (continued)
Ecodesign requirement Idle With load Description
Root Mean Square (RMS) of the supply
voltage
405.80 VAC 401.85 VAC
Supply active power 34 W 110.44 kW
Total harmonic distortion of the supply
voltage (UTHD)
1.16%
7.04%
Measured at idle state and at the rated
duty cycle for the system at the highest
output power.
Idle state power consumption by the
power source
34 W
Measured at idle state.
1
Efficiency
92.84%
Calculated at the rated duty cycle for
the system at the highest output power.
1 External devices were disconnected during idle measurement.
Gas connect console specifications
The part number and some specifications differ for each type of gas connect console.
Do not remove the inlet check valves from the gas connect console.
Figure 2 - Gas connect console dimensions
Specifications