Symptoms
Code Symptoms XPR models XPR action Code cancels with...
504 Chopper 1 cannot receive communications (at
least once-per-second) from the main control PCB
through the CAN.
All models Shut down Remote on-off
505 Chopper 2 cannot receive communications (at
least once-per-second) from the main control PCB
through the CAN.
XPR300,
XPR460
Shut down Remote on-off
506 Chopper 3 cannot receive communications (at
least once-per-second) from the main control PCB
through the CAN.
XPR460 Shut down Remote on-off
507 There is a problem with the CAN when power is
supplied to the cutting system.
All models None Remote on-off
508 The load on the CAN bus is more than capacity for
10 milliseconds or more.
All models None Remote on-off
514 The main control PCB cannot receive communica-
tions (at least once-per-second) from Chopper 1
through the CAN.
All models None Remote on-off
515 The main control PCB cannot receive communica-
tions (at least once-per-second) from Chopper 2
through the CAN.
XPR300,
XPR460
None Remote on-off
516 The main control PCB cannot receive communica-
tions (at least once-per-second) from Chopper 3
through the CAN.
XPR460 None Remote on-off
601 For a minimum of 30 seconds after power is sup-
plied to the cutting system, Chopper 1 does not
identify itself to the main control PCB through the
CAN.
All models Shut down Remote on-off
604 The inductor thermocouples for Chopper 2 were
sensed, but Chopper 2 was not sensed.
XPR300,
XPR460
None • Start process
• Set process
• Remote on-off
606 The main control does not receive CAN communica-
tions from Chopper 3 after power is supplied to the
cutting system.
XPR460 None • Start process
• Set process
• Remote on-off
Corrective action
1. Remove the power from the cutting system.
Diagnostics and Troubleshooting
8
318