Gas system screen
On this screen you can monitor the status of the TorchConnect console and the gas connect console. You
can also see which valves are active when the gas is flowing.
There are two view options for this screen.
Text view
In text view, text identifies real-time gas pressures and currently active valve states. When a valve is
active, the screen shows it as gray.
Both bar and psi units of measure are shown on this screen.
Diagram view
In diagram view a diagram shows:
Real-time gas pressures and currently active valve states.
Pressurized volumes and energized valves that show color when active and lines that change
thickness as the amount of pressure changes.
Pressure measurements and setpoints near the proportional valves and duty cycle (PWM)
sensors identified by the diagram.
This screen gives you the option to show either bar or psi units of measure.
You can do four tests from this screen:
Test Preflow
Test Cutflow
Test Pierceflow
Gas Leak Test
The gas leak test can be done with all gas connect consoles. Refer to Do
a gas leak test on page 295.
The test starts when you choose the button. When the button is active, the screen shows it as red. Active
valves show gray. The gases on Line A, Line B, and shield align with the process ID that you selected. The
gases flow for 60 seconds unless you choose the same button or choose another button that stops the
test.