Connect to the plasma power supply with discrete
Do these steps to connect the plasma power supply to the CNC with discrete cables.
Before you begin:
Remove external panels from the system components on page 101
Pinouts for the discrete interface cables on page 164
1. Remove the rear panel of the plasma power supply.
2. Put End A of the discrete cable through the hole in the bottom of the rear compartment in the plasma
power supply.
3. Connect J14 and J19 to their respective connectors on the control PCB in the plasma power supply.
4. Connect End B of the cable to the CNC.
5. Put End A of the discrete cable for the expansion PCB through the hole in the bottom of the rear
compartment of the plasma power supply.
6. Connect End A of the discrete cable for the expansion PCB to the J4 connector on the expansion
PCB.
7. Connect End B of the discrete cable for the expansion PCB to the CNC.
Figure 46 - Connect the discrete cable to the plasma power supply
Connect for Communication