Hypertherm XPR460 - Correct Sizes for Connectors on Hoses, Cables, and Leads

Hypertherm XPR460
532 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CAN cables
3-gas hose assembly for the Core gas connect console
4-gas hose assembly for the CorePlus gas connect console
5-gas hose assembly for the VWI or OptiMix gas connect console
Gas supply hoses
Bevel torch lead
Negative cables
Figure 6 - Minimum bend radius (measured inside diameter)
152.5 mm
(6 in.)
Correct sizes for connectors on hoses, cables, and leads
Make sure to use connectors that are the correct size on hoses, cables, and leads that connect from one
console to another.
The connectors for the console-to-console lead and hose assemblies have the following maximum
diameters:
56 mm (2.2 in.) for the pilot-arc cable and coolant-hose assembly
58 mm (2.3 in.) for the power cable, CAN cable, and gas-hose assembly
The following images show OptiMix assemblies as examples. The connectors on all console-to-console
assemblies (Core, CorePlus, VWI, and OptiMix) have the same diameter.
Figure 7 - Example OptiMix pilot-arc cable and coolant-hose assembly
Qualifications and Requirements
2
67811530Instruction ManualXPR460