Table 2 - Plasma power supply part numbers and specifications
Part
number
Voltage
(U
1
)
Phase
Fre-
quency
Rated input
current at kW
output (I
1
)
Regulatory approval
Safety/EMC
Power (± 10%)
(U
1
X I
1
X1.73)
078650 200
VAC
50 Hz
- 60 Hz
334 A cCSAus
078651 208
VAC
60 Hz 322 A cCSAus
078652 220
VAC
50 Hz
- 60 Hz
304 A cCSAus
078653 240
VAC
60 Hz 279 A cCSAus
078654 380
VAC
50 Hz
- 60 Hz
176 A CCC
078655
400
VAC
50 Hz
- 60 Hz
167 A CE, RCM, EAC, UKr, and AAA
078656
415
VAC
50 Hz 161 A CE, RCM, EAC, UKr, and AAA
078657 440
VAC
60 Hz 152 A cCSAus
078658 480
VAC
60 Hz 139 A cCSAus
078659 600
VAC
3
60 Hz 112 A cCSAus
115.78 kVA
Ecodesign requirements for CE models
Table 3 - Ecodesign requirements and data
Ecodesign requirement Idle With load Description
Output current 460.86 A
Output voltage 222.59 VDC
Output active power 102.53 kW
Measured at the rated duty cycle for the
system at the highest output power.