Symptoms
Code Symptoms XPR models XPR action Code cancels with...
588 Fan timeout codes can occur when the cooling
period is more than one hour.
A high ambient temperature can have an effect on
cooling time.
All models Shut down
Corrective action
1. Identify the over-temperature diagnostic codes that show on the XPR web interface.
2. Use the recommended troubleshooting steps for the codes that you see.
Refer to Diagnostic codes on page 278.
Troubleshooting for consumable part failure or no chopper
current
Diagnostic codes 610 – 615 and 626 – 628
Diagnostic codes 610 – 615 identify a consumable part problem. Diagnostic codes 626 – 628 identify a
condition when chopper current is not sufficient.
Symptoms
Code Symptoms XPR models XPR action Code cancels with...
610 Acatastrophic failure of a consumable part is found
on the Channel A Chopper 1 current signature.
All models
611 Acatastrophic failure of a consumable part is found
on the Channel B Chopper 1 current signature.
All models
612 Acatastrophic failure of a consumable part is found
on the Channel A Chopper 2 current signature.
XPR300,
XPR460
613 Acatastrophic failure of a consumable part is found
on the Channel B Chopper 2 current signature.
XPR300,
XPR460
614 Acatastrophic failure of a consumable part is found
on the Channel A Chopper 3 current signature.
XPR460
615 Acatastrophic failure of a consumable part is found
on the Channel B Chopper 3 current signature.
XPR460
Ramp down Remote on-off
Diagnostics and Troubleshooting
8
341811530Instruction ManualXPR460