Torch symbols
Electrode
Nozzle
Shield
Torch
Torch, HyDefinition
Valve states during operation
During each stage of cutting system operation, different valves are active (ON) or inactive (OFF). The type
of gas connect console and the type and timing of the active process changes the valves that are active or
inactive.
Refer to the CNC or XPR web interface to see the most current information about the state (ON-OFF) of
each valve:
For information about how to view valve states on the CNC, refer to the instruction manual that came
with your CNC.
To view valve states on the XPR web interface:
a Use the XPR web interface to select the process you want to view.
b Go to the Gas System screen.
Refer to Gas system screen on page 192. On this screen you
can see which valves are active when the gas is flowing. Active
valves are indicated with a gray highlight.
c On the Gas System screen, enable the desired mode (Test Preflow, Test Pierceflow, or Test