Examples of input circuits
If it is necessary to design your own circuit to use the remote on-off feature, you can refer to these input
circuit diagrams as examples.
There are three types of interfaces for input circuits.
It is the responsibility of the system integrator to make sure that circuit designs obey all applicable national
and local codes.
Relay interface
A XPR
B CNC
1 The life of the external relay can be extended if you add a resistor-capacitor series in parallel with the relay contacts.
A metalized-polyester capacitor – 0.022 μF 100 V or higher – is a good example.
2 Power ground
3 External relay (AC or DC)
4 Output from CNC
5 +24 VDC
Optocoupler interface
Connect for Communication
4
205811530Instruction ManualXPR460