Figure 46 - Connect the discrete cable to the plasma power supply (continued)
2B Expansion PCB connectors: Necessary for redundant remote on-off feature, alternate 24 VDC power input, and
analog estimated arc voltage output.
Pinouts for the discrete interface cables
Use these tables to identify the signals, pin numbers, and wire colors in interface cables with discrete
connectors.
Table 25 - Pinout for J14 on the discrete cable
To the plasma
power supply
J14 pin
Input/
output
Signal Function
Wire
color
1 Remote on/off + Red
2
Input
1, 2
Remote on/off -
When the input is open, the power to the plasma
power supply, the consoles, and the contactors is dis-
abled.
Black
3 Plasma start + White
4
Input
3
Plasma start -
The CNC starts preflow. If the hold input is not active,
the CNC continues with the plasma arc. The plasma
power supply stays in preflow as long as the hold
input stays active.
Black
5 Motion + Green
6
Output
3
Motion -
Tells the CNC that an arc transfer has occurred and
to begin machine motion after the CNC pierce delay
time.
Black
7 Hold + Blue
8
Input
1
,
4
Hold -
The CNC delays plasma arc start. This signal is usually
used in combination with the Start signals to synchro-
nize multiple torches. Start this signal at the same time
as the Plasma Start signal. Stop this signal to fire the
torch.
Black
9 Shield pierceflow + Yellow
10
Input
1
Shield pierceflow -
The CNC tells the plasma system to continue the
shield preflow until after the pierce-delay time. Start
this signal at the same time as the Plasma Start signal.
Stop this signal when the pierce time is complete.
Black
11 F+24V CNC Available 24 VDC (200 mA maximum) Brown
12
Output
5
F PWRGND Ground Black
1 Inputs are optically isolated. It is necessary to supply them with 24 VDC at 12.5 mA or dry-contact closure at 8 mA.
2 If J27 of the main control PCB has a jumper between pin 2 and pin 3, refer to Pinouts for the discrete cable for the expansion PCB on page
165, Install a redundant remote on-off switch on page 207, and Examples of output circuits on page 202.
Connect for Communication
4
164
811530 Instruction Manual XPR460