Symptoms
Code Symptoms XPR models XPR action Code cancels with...
706 The P1 pressure sensor in the TorchConnect con-
sole is not found.
707 The P2 pressure sensor in the TorchConnect con-
sole is not found.
708 The P3 pressure sensor in the TorchConnect con-
sole is not found.
709 The P4 pressure sensor in the TorchConnect con-
sole is not found.
710 The P5 pressure sensor in the TorchConnect con-
sole is not found.
711 The P14 pressure sensor in the TorchConnect con-
sole is not found.
712 The P6 pressure sensor in the gas connect console
is not found.
713 The P7 pressure sensor in the gas connect console
is not found.
714 The P8 pressure sensor in the gas connect console
is not found.
715 The P9 pressure sensor in the gas connect console
is not found.
All models Ramp down Set process
Remote on-off
Corrective action
1. Remove the power from the cutting system.
2. Examine the pressure transducer for the diagnostic code that you see.
For example:
If the code shows P1-TCC, examine the P1 pressure transducer in the TorchConnect console.
If the code shows P6-GCC, examine the P6 pressure transducer in the gas connect console.
3. Make sure that the pressure transducer is correctly connected to:
TorchConnect console control PCB
Gas connect console control PCB
4. Install the pressure transducer correctly if you find loose or incorrect connections.
Diagnostics and Troubleshooting
8
357811530Instruction ManualXPR460