Table 34 - Diagnostic code descriptions (continued)
Code Priority Description
XPR
models
Corrective action
504 Failure Ch1->Main CAN t/o All models
505 Failure Ch2->Main CAN t/o
XPR300
,
XPR460
506 Failure Ch3->Main CAN t/o XPR460
CAN communication troubleshooting for choppers on
page 317
507 Failure Main no CAN All models
508 Error CAN Busy All models
1. CAN communication troubleshooting for choppers
on page 317
2. CAN communication troubleshooting for gas
connect consoles on page 311
3. CAN communication troubleshooting for mixing
modules in OptiMix consoles on page 313 (if
applicable)
4. CAN communication troubleshooting for
TorchConnect consoles on page 316
509 Failure Cooler->Main CAN t/o XPR460 This code occurs when the cooler does not receive
CAN communications for the main control at least
once per second. If you continue to get this code,
speak to your cutting machine supplier or regional
Hypertherm Technical Service team.
XPR action: Shut down
Code cancels with: Remote on-off
510 Failure Main->GCC CAN t/o All models CAN communication troubleshooting for gas connect
consoles on page 311
511 Failure Main->Mix CAN t/o All models CAN communication troubleshooting for mixing mod-
ules in OptiMix consoles on page 313
513 Failure Main->TCC CAN t/o All models CAN communication troubleshooting for TorchCon-
nect consoles on page 316
514 Failure Main->Ch1 CAN t/o All models
515 Failure Main->Ch2 CAN t/o XPR300,
XPR460
516 Failure Main->Ch3 CAN t/o XPR460
CAN communication troubleshooting for choppers on
page 317
Diagnostics and Troubleshooting
8
279811530Instruction ManualXPR460

Table of Contents