DIP switch 2 positions
1 Micro-controller DFU programming
mode
• ON = DFU
• OFF = Run
Default is OFF
2 3.3 V logic power • ON = USB OTG
• OFF = Internal power supply
Default is OFF
3 RS-422 Serial ID0 – Default is OFF
4 RS-422 Serial ID1 – Default is OFF
DIP switch 3 positions
1 Wireless module programming • ON = Enabled
• OFF = Disabled
Default is OFF
2 Wireless module transmit • ON = From micro-controller
• OFF = Disabled (must be OFF for
J20 programming)
Default is ON
3 Wireless module transmit • ON = From J20 programming
connector
• OFF = Disabled (must be OFF for
usual operation)
Default is OFF
4 Wireless enable • ON = Wireless disabled
• OFF = Wireless enabled
Default is OFF
DIP switch 4 positions
1 Alternate boot mode – Default is OFF
2 Console boot mode – Default is OFF
3 Protocol 1 – EtherCAT • Switch 3 = OFF
• Switch 4 = OFF
• Switch 5 = OFF
Default is OFF
4 Protocol 2 (for future use) • Switch 3 = ON
• Switch 4 = OFF
• Switch 5 = OFF
Default is OFF
5 Protocol 3 (for future use) • Switch 3 = OFF
• Switch 4 = ON
• Switch 5 = OFF
Default is OFF
Redundant remote on-off is set to disabled (OFF) by default, with a
jumper across pin 1 and pin 2 of the J27 connector. For more information,
Diagnostics and Troubleshooting
8
384
811530 Instruction Manual XPR460