terminal and the brass PE block terminal and use a straight lug with a 0.50 inch inner diameter
hole for each connection.
Figure 39 - Main power cord wire color and terminal location
Wire color codes for North America
Wire color codes for Europe, Asia, and
most locations outside of North Amer-
ica
1 TB1 terminal
2 U Black Black
3 V White Blue
4 W Red Brown
5 GND (PE) (earth
ground)
Green/yellow Green/yellow
3. Comply with national and local electrical codes to connect the W, V, and U power leads from the main
power cord to the line-disconnect switch.
Installation
3
152
811530 Instruction Manual XPR460